OUTPUT RATINGS |
|
CH1/CH2 Independent |
0 ~ 30V / 0 ~ 6A ; 0 ~ 60V / 0 ~ 3A |
|
CH1/CH2 Series |
0 ~ 60V / 0 ~ 6A ; 0 ~ 120V / 0 ~ 3A |
|
CH1/CH2 Parallel |
0 ~ 30V / 0 ~ 12A ; 0 ~ 60V / 0 ~ 6A |
|
CH3 |
0.1 ~ 5V / 3A |
|
VOLTAGE REGULATION |
|
Line |
≦0.01% + 3mV |
|
Load |
≦0.01% + 5mV (rating current ≦6A)
≦0.01% + 8mV (rating current ≦12A) |
|
Ripple & Noise |
≦5mVrms (5Hz ~ 1MHz );≦ 50mVpp (20Hz ~ 20MHz) |
|
Recovery Time |
≦100 s(50% load change, minimum load 0.5A) |
|
CURRENT REGULATION |
|
Line |
≦0.2% + 3mA |
|
Load |
≦0.2% + 3mA |
|
Ripple & Noise |
≦3mArms |
|
TRACKING OPERATION |
|
Tracking Error |
≦0.5% + 10mV of master |
|
Series Regulation |
≦300mV |
|
Ripple & Noise |
≦10mVrms (5Hz ~ 1MHz);≦100mVpp (20Hz ~ 20MHz) |
|
OUTPUT ON/OFF RESPONSE TIME |
|
Voltage Up (10% ~ 90%) |
≦100ms ( ≦ 95% rating load) |
|
Voltage Down (90% ~ 10%) |
≦100ms ( ≧ 10% rating load) |
|
OVP |
|
Accuracy |
± (0.5% of reading + 0.5V) |
|
METER |
|
Type |
3 1/2 digits 0.5" LED display |
|
Accuracy |
± (0.5% of reading + 2 digits) |
|
Resolution |
100mV/10mA |
|
INSULATION |
|
Chassis & Terminal |
100M or above (DC 1000V) |
|
Chassis & AC code |
100M or above (DC 1000V) |
|
TEMPERATURE COEFFICIENT |
|
Voltage |
≦ 100ppm/ C + 3mV |
|
Current |
≦ 150ppm/ C + 3mA |
|
REMOTE CONTROL |
|
Output On/Off |
|
FAN NOISE |
|
≦50dB |
|
OPERATION ENVIRONMENT |
|
Ambient temperature 0 ~ 40℃ ; Relative humidity ≦ 80% |
|
STORAGE ENVIRONMENT |
|
Ambient temperature -10 ~ 70℃ ; Relative humidity ≦70% |
|
POWER SOURCE |
|
AC 115V/230V ±15%, 50/60Hz |
|
ACCESSORIES |
|
User manual x 1, Power code x 1, Test lead GTL-104 x 2, GTL-105 x 1 |
|
DIMENSIONS & WEIGHT |
|