Signal Processor (EXTECH 9811) |
Power Input/Output Channels |
Input 3CH with independent AC/DC Power measurement / Output 6CH with independent DC measurement |
Signal Output Relay Contact |
PASS, FAIL, TESTING:250V,2A maximum |
Remote Control |
Independent Left and Right with 4 Bit TTL Input and 3 Relay Contact( 250V,2A maximum) |
Input /Output Terminal |
Input: Three Port Selection 250VAC 15A maximum, Output: 40A maximum |
Input Measurement Board |
|
Range |
Resolution |
Accuracy |
AC Voltage, V |
00.00– 30.00 |
0.01V |
± (1% of reading + 1 count) |
0.0 – 300.0 |
0.1V |
± (1% of reading + 1 count) |
AC Current, A(RMS) |
0.0000 – 0.3500 |
0.0001A |
± (1% of reading + 5 counts) |
0.000 – 3.500 |
0.001A |
± (1% of reading + 5 counts) |
0.00 – 15.00 |
0.01A |
± (1% of reading + 2 counts) |
AC Current, A(Peak) |
0.00– 200.00 |
0.1A |
± (2% of reading + 4 counts) |
AC Power, W |
00.00 – 35.00 |
0.01W |
± (1% of reading + 5 counts) |
0.0– 350.0 |
0.1W |
± (1% of reading + 1 count) |
0– 4000 |
1W |
± (1% of reading + 1 count) |
Output Measurement Board |
RIPPLE & NOISE Bandwidth |
35~20MHZ |
Input Impedance |
AC coupled 50W |
Range 1, mVp-p (100 ~ 1M Hz ) |
0.0– 300.0mV |
0.1mV |
±(2% of Reading + 2% of F.S.) |
Range 2, mVp-p (100 ~ 1M Hz ) |
0 – 3000mV |
1mV |
±(2% of Reading + 2% of F.S.) |
Range 1, mVp-p (<100HZ/ >1MHZ ) |
0.0– 300.0mV |
0.1mV |
-3dB - ( 2% of Reading + 2% of F.S.) ~ ( 2% of Reading + 2% of F.S.) |
Range 2, mVp-p (<100HZ/ >1MHZ ) |
0 – 3000mV |
1mV |
-3dB - ( 2% of Reading + 2.5% of F.S.) ~ ( 2% of Reading + 2.5% of F.S.) |
Overshoot |
Range 1, V |
0.00 – 35.00 |
0.01V |
± (1% of reading + 0.2% of F.S) |
Range 2, V |
30.0 – 200.0 |
0.1V |
± (1% of reading + 0.2% of F.S) |
DC Current Measurement |
Range 1 ,mA |
0.000 –3.000 |
0.001mA |
±(0.3% of reading + 0.2% of F.S) |
Range 2 ,mA |
0.00 –30.00 |
0.01mA |
±(0.3% of reading + 0.2% of F.S) |
Range 3 ,A *1 |
0.00– 30.00 |
0.01A |
± (0.5% of reading + 0.2% of F.S) |
Programmable Output Voltage |
DC Voltage , V(Max. 10mA) |
0.000-8.000 |
0.002V |
±(0.3% of reading + 2 counts) |
External DC Voltage Measurement |
DC Voltage , V |
0.000-8.000 |
0.002V |
±(0.3% of reading + 2 counts) |
Short Current Measurement |
DC Current ,A |
0.0– 200.0 |
0.1A |
± (2% of reading + 4 counts) |
Timing Analyzer (EXTECH 9820) |
Input port |
300Vp-p Signal Differential Input |
Number of channels |
12 Channel (Include PG *1 , Sync *1) Isolated DC 500V |
Trigger level, two Range |
RN1 ± 0-20V , RN2 ±0-200V |
Trigger level, two Accuracy |
±1.0% + 2 counts |
Measurement Timer, mS |
Range |
Resolution |
Accuracy |
|
0.0~9999.9 |
100μs |
±(0.2% + 2 counts) |
Programmable AC Power Source (EXTECH 6130) |
MODEL 6130 |
3KVA/0-300V/Max. 25.2A |
Power Rating |
3000VA |
Output Voltage,AC |
0-300V AutoRange |
Max AC output Current(RMS) |
12.6AHighVoltageRange / 25.2ALowVoltageRange |
Output Frequency |
Range: 45-500HZ, Resolution: 0.1HZ, Accuracy: ±0.01% of setting |
Harmonic Distortion |
THD<0.5% at 45-500Hz (Resistive Load) |
Load Regulation |
± (0.5% of output +0.5V) at Resistive Load |
Turn On Phase Angle |
0-360° Resolution: 1°, Accuracy: ±1°(45-65HZ) |
Electronic Load (3310A ×2) |
MODEL 3310A |
60V/60A/150W |
|
Range |
Resolution |
Accuracy |
CC MODE |
0-3A/0-30A |
0.75mA/7.5mA |
±(0.2% of Setting + range) |
CR MODE |
2-8KΩ/0.1-2Ω |
0.5mS/0.25mΩ |
±(0.2% of Setting + range) |
CV MODE |
0-60V |
0.015V |
±(0.1% of Setting + range) |
DYNAMIC MODE |
THigh/TLow 50μSec TO 9.999Sec |
OPERATION |
Slew Rate 0.5-125mA/μSec, 5mA-1.25A/μSec. |
LoadON Voltage |
0-3V ,Adjustments are made through the Load module VR1 resistance , Output voltage default is 1V. |
Protection |
OCP, OPP, OVP, OTP |
Programmable DC Power Supply(PPS-2017) OVP |
MODEL 2017 |
60V/3A/180W |
|
Range |
Resolution |
Accuracy |
Output Voltage,DC |
0-60V |
20mV |
0.05% ± 2 LSB |
Current,DC |
0-3.0A |
1mA |
0.15% ± 5 LSB |
Programmable DC Power Supply(PPS-2016) |
MODEL 2016 |
20V/10A/200W |
|
Range |
Resolution |
Accuracy |
Output Voltage,DC |
0-20V |
5mV |
0.05% ± 2 LSB |
Current,DC |
0-10A |
3mA |
0.15% ± 5 LSB |
System Controller |
Controller |
IPC P4 -2.4GHZ with DDR 256MB,CD-ROM 52 SPEED, FDD 1.44MB,HDD 40GB |
Operational Environment |
Windows XP with Excel XP |
Display monitor |
15" TFT LCD Display |
Interational Board |
NI GPIB Card (PCI) |
System General Specifications |
Dimension and Weight |
35U Equipment Rack, 180Kg |
Electrical |
230 VAC±10% , 50/60Hz 15A Single Phase |
Environment |
40℃,RH 20~80% |
Option maximum Input 4CH/Output 8CH. Product specifications are subject to change without notice. |
*1 Sofware measurement are not available. |