 SPECIFICATIONS  | 
| 
 MODEL  | 
 6303  | 
 6306  | 
 6309  | 
 6315  | 
 6330  | 
 6360  | 
 6390  | 
| 
 INPUT  | 
| 
 Phase  | 
 1¢  | 
 3¢  | 
| 
 Voltage  | 
 230Vac±15%  | 
 220/380Vac±10%  | 
| 
 Frequency  | 
 47-63Hz  | 
| 
 OUTPUT  | 
| 
 Power rating  | 
 Single-Phase Power  | 
 1KVA  | 
 2KVA  | 
 3KVA  | 
 5KVA  | 
 10KVA  | 
 20KVA  | 
 30KVA  | 
| 
 Total Power  | 
 3KVA  | 
 6KVA  | 
 9KVA  | 
 15KVA  | 
 30KVA  | 
 60KVA  | 
 90KVA  | 
| 
 Max. Current (r.m.s)  | 
 0-150V  | 
 8.4A  | 
 16.8A  | 
 25.2A  | 
 42.0A  | 
 84.0A  | 
 168.0A  | 
 252.0A  | 
| 
 0-300V  | 
 4.2A  | 
 8.4A  | 
 12.6A  | 
 21.0A  | 
 42.0A  | 
 84.0A  | 
 126.0A  | 
| 
 Phase  | 
 3¢/4W  | 
| 
 Waveform Distortion  | 
 < 1% at 45-500Hz (Resistive Load)  | 
| 
 Crest Factor  | 
 > 3  | 
| 
 Line to Phase Regulation  | 
 ± (0.5% of output +0.5V) at Resistive Load  | 
| 
 Line to Line Regulation  | 
 ± (1% of output +1V) at Resistive Load  | 
| 
 Deviation of phase angle  | 
 120° < ±1° at Load Balance, 120° < ±2.5° at 100% Load Unbalance  | 
| 
 Response Time  | 
 < 2 msec  | 
| 
 SETTINGS  | 
| 
 Voltage  | 
 PhaseRange  | 
 0-150V/0-300V Selectable  | 
| 
 Resolution  | 
 0.1V  | 
| 
 Accuracy  | 
 ±(1% of setting + 2counts)  | 
| 
 Frequency  | 
 Range  | 
 45-500Hz FullRange Adjust  | 
| 
 Resolution  | 
 0.1Hz at 45-99.9Hz , 1Hz at 100-500Hz  | 
| 
 Accuracy  | 
 ±0.02% of setting  | 
| 
 MEASUREMENT  | 
| 
 Voltage  | 
 PhaseRange  | 
 0.0-300.0V  | 
| 
 LineRange  | 
 0.0-520.0V   | 
| 
 Resolution  | 
 0.1V  | 
| 
 Accuracy  | 
 ± (1% of reading + 2counts)  | 
| 
 Frequency  | 
 Range  | 
 0.0-500.0Hz  | 
| 
 Resolution  | 
 0.1Hz  | 
| 
 Accuracy  | 
 ±0.1Hz  | 
| 
 Current (r.m.s)  | 
 Range  | 
 L  | 
 0.000-3.500A  | 
 0.00-35.00A  | 
| 
 H  | 
 3.00-35.00A  | 
 30.00-350.0A  | 
| 
 Resolution  | 
 L  | 
 0.001A  | 
 0.01A  | 
| 
 H  | 
 0.01A  | 
 0.1A  | 
| 
 Accuracy  | 
 L  | 
 ± (1% of reading +5counts)  | 
 ± (1% of reading +2counts)  | 
| 
 H  | 
 ± (1% of reading +1count)  | 
 ± (1% of reading +1count)  | 
| 
 Power  | 
 Range  | 
 L  | 
 0.0-350.0W  | 
 0.000-3.500KW  | 
| 
 H  | 
 300-4000W  | 
 3.00-40.00KW  | 
| 
 Resolution  | 
 L  | 
 0.1W  | 
 0.001KW  | 
| 
 H  | 
 1W  | 
 0.01KW  | 
| 
 Accuracy  | 
 L  | 
 ± (1.5% of reading +5counts)  | 
 ± (1.5% of reading +5counts)  | 
| 
 H  | 
 ± (1.5% of reading +1count)  | 
 ± (1.5% of reading +1count)  | 
| 
 Power Factor  | 
 Range  | 
 0.000-1.000  | 
| 
 Resolution  | 
 0.001  | 
| 
 Accuracy  | 
 Calculated and displayed to three significant digits  | 
| 
 GENERAL  | 
| 
 PLC Remote  | 
 I/P:ON/OFF, P1, P2, P3, O/P:Processing  | 
| 
 Memory  | 
 8 Memoies, 5steps per memory for Voltage, Frequency, Test Time, Delay time and  Current, Power, Power Factor Hi, Lo Limit setting.  | 
| 
 Timer  | 
 0=Continuous, 1-9999. (Unit: sec, minute, hour selectable)  | 
| 
 Auto Loop Cycle  | 
 0=Continuous, OFF=Loop Once, 2~9999. (Unit:×1, ×10, ×100)  | 
| 
 Auto Voltage Adjust  | 
 Enable it for improve voltage regulation within ±0.1V  | 
| 
 Efficiency  | 
 ≧80%(at Full Load )  | 
 ≧85%(at Full Load )  | 
| 
 Protection  | 
 Over Load , Short Circuit , Over Temperature  | 
| 
 Calibration  | 
 Front Panel Calibration  | 
| 
 Interface (Option)  | 
 GPIB/RS232   | 
| 
 Environment  | 
 0-40℃/20-80%RH  | 
| 
 Dimension (W×H×D) mm  | 
 430×729 ×650, 14U  | 
 430×729 ×650, 14U  | 
 600×818 ×900, 16U  | 
 600×818 ×900, 16U  | 
 600×952 ×900, 19U  | 
 600×1390 ×900, 28U  | 
 900×1725 ×1200, 35U  | 
| 
 Net Weight  | 
 105Kg  | 
 120Kg  | 
 222Kg  | 
 290Kg  | 
 460Kg  | 
 760Kg  | 
 1200Kg  | 
| 
 product specifications are subject to change without notice.  |