产品中心 > 数据采集器/记录仪 > 记录仪 > 标准精度温湿度记录仪F1620A-S
  • 标准精度温湿度记录仪F1620A-S

  • 产品编号:10753
  • 产品名称:标准精度温湿度记录仪
  • 产品型号:F1620A-S
  • 订货编号:
  • 市 场 价:¥24480.00
  • 促 销 价:
  • 状    态:
  • 产    地:美福禄克
  • 简要参数:
    标准精度温湿度记录仪,工作范围0℃~50℃、0% RH~100% RH,已校准温度准确度 15℃~35℃为±0.25℃,已校准相对湿度准确度20% RH~70% RH为±2% RH,最多两个传感器输入,400000个标准的带数据/时间戳的独立读数,仪器识别、测量值、由密码保护的终端网页等嵌入式网页界面功能,针对温度、温度变化速率、相对湿度、相对湿度变化速率以及故障情况等条件提供由密码保护的声、光报警和外部报警功能,240x128 图形黑白 LCD显示屏幕,以太网、RS-232、RF(可选)接口,包括一个标准精度传感器、壁式支架、RS-232电缆。
  • 人    气:1896

产品介绍

The DewK measures temperature to ?0.125 癈 and humidity to ?1.5 % on two channels, and displays it on a big, clear screen. Ethernet, wireless (optional), or RS-232 will allow you to network as many DewKs as you抎 like. And the LogWare III software will allow real-time logging of multiple DewKs, data storage to your computer and seamless integration with MET/CAL?software.

Features at a glance:

  • Superior accuracy

  • Network enabled

  • Powerful logging and analysis tools

  • Two interchangeable calibrated sensors

  • Huge memory

  • Upgraded software

Accuracy
Two types of sensors are available. The high-accuracy sensor (揌 model) reads temperature to ?0.125 癈 over a calibrated range of 16 癈 to 24 癈. Relative humidity readings are to ?1.5 % RH from 20 % RH to 70 % RH.

The standard-accuracy sensor (揝 model) reads temperature to ?0.25 癈 over its calibrated range of 15 癈 to 35 癈. Relative humidity readings are to ?2 % RH from 20 % RH to 70 % RH.

All DewK sensors come with NVLAP accredited certificates of calibration for both temperature and humidity, complete with data and NIST traceability.

Ethernet and wireless capability
With its built-in Ethernet RJ45 jack, multiple DewKs can be monitored from the same screen using LogWare III client-server software. Ethernet also gives you the possibility for remote connectivity over the internet, so you can monitor critical conditions while you抮e away.

Cables running along the floor can be a safety hazard, and cables hanging from the ceiling and walls are an eyesore. With the DewK, simply connect your computer through an RF modem up to 100 ft away, without the clutter of all the extra cables.

If you need a printout, send data to a printer through the RS-232 interface in real time.

Math and statistical functions
In addition to temperature and humidity, the DewK calculates dew point, heat index, and rates of change for both temperature and humidity. Min, max, and a variety of other statistics are also calculated and can be shown on-screen. Daily summary statistics, including min, max, and maximum rates of change are stored for the most recent sixty days.

Calibrated sensors
With inputs for two sensors, each measuring both temperature and relative humidity, one DewK can monitor two locations at the same time. Both sensors can be run via extension cables to remote locations up to 100 feet away, or one sensor can be directly mounted to the top of the DewK.

Each sensor is calibrated for both temperature and humidity by Fluke Calibration. The calibration constants assigned to the sensors reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably between different DewKs, and the recalibration of sensors doesn抰 require an accompanying DewK.

Sensors may also be assigned a unique identifier (up to 16 characters) to facilitate record keeping by matching the sensor identifier with the collected data. Each DewK ships with one sensor, with additional sensors available from. Spare sensors may also be purchased as a kit, which includes a case for the sensor, a wall mounting bracket, and a 25-foot extension cable.

Memory
The DewK has enough on-board memory to store up to 400,000 date- and times stamped data points. That抯 two years?worth of data for both measurements from two sensors if readings are taken every ten minutes!

Alarms and battery backup
Alarm settings can be set up quickly in the DewK based on temperature, the rate of change in temperature, RH, the rate of change in RH, and instrument fault conditions. Alarms can be both visual (flashing display) and audible (beeping). Likewise, alarm settings can be set up and events triggered in LogWare III. The DewK is also equipped with a 0 to 12 volt alarm output that can trigger a process control system.

A backup battery shuts down the DewK抯 display but maintains measurements for up to 16 hours in the event of a power failure.

Large, easy-to-read display
Want to view data from across the room? Want to view data from two temperature and two humidity inputs simultaneously? Want to view data graphically, statistically, or both? At the same time?! The DewK does everything you could want梠r at least everything we could think of. Up to sixteen different display setups can be stored and recalled at the touch of a single button. And all 16 can be easily modified, so you get exactly what you want.

Specifications
Operating Range 0 癈 to 50 癈 (32 癋 to 122 癋); 0 % RH to 100 % RH
Calibrated Temperature Accuracy (揌?Model) ?0.125 癈 from 16 癈 to 24 癈 (?0.225 癋 from 60.8 癋 to 75.2 癋)
Calibrated temperature Accuracy (揝?Model) ?0.25 癈 from 15 癈 to 35 癈 (?0.45 癋 from 59 癋 to 95 癋)
Calibrated RH Accuracy (揌?Model) ?1.5 % RH from 20 % RH to 70 % RH
Calibrated RH Accuracy (揝?Model) ?2 % RH from 20 % RH to 70 % RH
Expected Extrapolated Performance (Uncertified) ?0.5 癈 (?0.9 癋) outside calibrated range ?3 % RH outside calibrated range
Delta Temperature Accuracy ?0.025 癈 for ?1 ?changes within 15 癈 to 35 癈 (?0.045 癋 for ?1 ?changes within 59 癋 to 95 癋)
Temperature Resolution User selectable up to 0.001 癈/癋 on front-panel display (0.01?recorded)
Delta Humidity Accuracy ?1.0 % RH for ?5 % changes within 20 % RH to 70 % RH
RH Resolution User selectable up to 0.01 % on front-panel display (0.1 % recorded)
Inputs Up to two sensors, measure temperature and relative humidity, detachable, cable-extendable, interchangeable, self-contained calibrations, may be assigned unique 16-character identifications
Display 240 x 128 graphics monochrome LCD, displays password-protected temperature/humidity data graphically, numerically, and statistically (one or both channels); 16 pre-defined, user-changeable screen setups
Memory 400,000 typical individual date/time-stamped readings
Alarms Password-protected visual, audible, and external alarms for temperature, temperature rate, RH, RH rate, and fault conditions
Alarm Port Output 2.5 mm two-conductor subminiature plug, 0 V normal, 11 to 12 V active, sources up to 20 mA
Connectivity Ethernet, RS-232, RF (optional)
Ethernet RJ45 jack, 10 Base-T or 100 Base-TX; static or dynamic (DHCP client) IP address assignment
Web Page Embedded web page interface features: instrument identification, measurements, password-protected terminal page; can be disabled
Wireless Option Requires wireless modem. 802.15.4 (underlies Zigbee), 2.4 GHz frequency, 1 mW transmit power, 30 m (100 ft) typical unobstructed range; can be disabled
Mounting Wall mounted (hardware included) or set on a bench top
Power 12 V dc from external 100 to 240 V dc power supply
Battery Backup Standard 9 V battery enables continued measuring during power disruptions
Size (DewK) ( HxWxD ) 125 mm x 211 mm x 51 mm (4.9 x 8.3 x 2.0 in)
Size (Sensors) ( LxDia ) 79 mm x 19 mm (3.1 x 0.75 in)
Weight 0.7 kg (1.5 lb)
Calibration Certificate of NIST-traceable NVLAP accredited temperature and humidity calibration included; As Found and As Left data supplied at three temperature points and three humidity points each at 20 癈 (68 癋); Complies with NCSL/ISO/IEC 17025:2000 and ANSI/NCSL Z540-1-1994
LogWare III (Optional Software) Requirements include: Microsoft?Windows?2000 (SP4) or XP (SP2) operating system, IBM compatible Intel Pentium?IV 1 GHz PC processor or better, 512 Mb RAM (1Gb or more recommended), 200 Mb HDD space for installation (additional free space recommended for data storage), CD-ROM drive for installation